If the number of parasites in the stool specimens is low,
examination of a direct wet mount may not detect them, hence the stool
should be concentrated to increase the sensitivity of the microscopic
detection method. Concentration technique increase the sensitivity
Formal ether sedimentation technique is a commonly used concentration
technique.
Fig 1: Formal Ether Sedimentation Technique |
Materials required for Formal Ether Sedimentation techniques are
1. Glass container
2. Guaze
3. Funnel
4. Centrifuge tube (15ml capacity)
5. Centrifuge
6. Physiological saline (0.85% w/v Nacl)
7. 10% formal dehyde
8. Ether (ethyl acetate)
9. Test tubes with stopper
10. Glass rod
11. Iodine
12. Microscope
Procedure for Formal Ether Sedimenation Technique
1. Transfer half teaspoonful of faeces in 10 ml of water in a glass container and mix thoroughly.
2. Place 2 layers of gauze in a funnel and strain the contents into a 15 ml centrifuge tube.
3. Centrifuge for 2 minutes at about 500 g.
4. Discard the supernatant and resuspend the
sediment in 10 ml of physiological saline. Centrifuge at 500 g and
discard the supernatant.
5. Resuspend the sediment in 7 ml of 10% formaldehyde (1 part of 40% formalin in 3 parts of saline).
6. Add 3 ml of ether (or ethyl acetate).
7. Close the tube with a stopper and shake
vigorously to mix. Remove the stopper and centrifuge at 500g for 2
minutes.
8. Rest the tube in a stand. Four layers now
become visible the top layer consists of ether, second is a plug of
debris, and third is a clear layer of formalin and the fourth is the
sediment (Fig 1).
9. Detach the plug of debris from the side of the
tube with the aid of a glass rod and pour off the liquid leaving a
small amount of formalin for suspension of the sediment.